[ Previous | Next | Table of Contents | Index | Library Home |
Legal |
Search ]
Technical Reference: Base Operating System and Extensions, Volume 1
Queries and controls the battery
status.
PM (Power Management) Library
(libpm.a)
#include <pmlib.h>
int pmlib_request_battery (cmd, pmb);
int cmd;
pmlib_battery_t *pmb;
cmd
| Determines the action to be taken by the pmlib_request_battery
subroutine and is one of the following values:
- PMLIB_QUERY_BATTERY
- Queries the battery state.
- PMLIB_DISCHARGE_BATTERY
- Discharges the battery.
|
pmb
| Points to the following pmlib_battery_t structure:
typedef struct _pmlib_battery {
int attribute; /*battery attribute*/
int capacity; /*battery capacity*/
int remain; /*current remain capacity*/
int refresh_discharge_capacity;
int refresh_discharge_time; /*discharge time*/
int full_change_count;
} pmlib_battery_t;
|
When cmd is
PMLIB_QUERY_BATTERY, the returned pmb.attribute
is bit-wise OR of following values:
PMLIB_BATTERY_SUPPORTED
| Battery is supported.
|
PMLIB_BATTERY_EXIST
| Battery exists.
|
PMLIB_BATTERY_NICD
| Battery is NiCd
|
PMLIB_BATTERY_CHARGING
| Battery is being charged.
|
PMLIB_BATTERY_DISCHARGING
| Battery is being discharged.
|
PMLIB_BATTERY_AC
| AC adapter is in use.
|
PMLIB_BATTERY_DC
| Battery is in use.
|
PMLIB_BATTERY_REFRESH_REQ
| Need to refresh battery.
|
The
pmlib_request_battery subroutine queries the battery information or
requests to discharge the battery. The pmlib_request_
subroutine can be called by any user.
Upon successful completion,
PMLIB_SUCCESS is returned. If the
pmlib_request_state subroutine fails, PMLIB_ERROR is
returned and errno variable is set to an error code.
ESRCH
| PM daemon is not running.
|
EINVAL
| Invalid argument.
|
The
pmlib_request_battery subroutine is part of the Base Operation
System (BOS) Runtime.
The
pmlib_get_event_notice (pmlib_get_event_notice Subroutine) subroutine,
pmlib_request_state (pmlib_request_state Subroutine) subroutine, pmlib_request_parameter (pmlib_request_parameter Subroutine) subroutine,
pmlib_register_application (pmlib_register_application Subroutine) subroutine.